{"id":778,"date":"2025-02-06T14:00:55","date_gmt":"2025-02-06T12:00:55","guid":{"rendered":"http:\/\/www.madridlicencias.com\/blog\/?p=778"},"modified":"2016-03-01T01:03:00","modified_gmt":"2016-02-29T23:03:00","slug":"actualizacion-comentarios-normativa-incendio","status":"publish","type":"post","link":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/","title":{"rendered":"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio)"},"content":{"rendered":"<p style=\"text-align: justify;\">Se han <strong>actualizado<\/strong> los comentarios incorporados a los documentos <strong>DB-SI<\/strong> (Seguridad frente a incendio), del C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n (<strong>CTE<\/strong>). Os remitimos un breve <strong>resumen<\/strong> para vuestra informaci\u00f3n:<\/p>\n<p style=\"text-align: justify;\"><strong><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-784\" src=\"http:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg\" alt=\"licencia normativa indendios\" width=\"884\" height=\"323\" srcset=\"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg 884w, https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios-300x110.jpg 300w, https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios-768x281.jpg 768w\" sizes=\"auto, (max-width: 884px) 100vw, 884px\" \/>DB SI con comentarios<\/strong><br \/>\nEn el presente documento indicamos los <strong>comentarios<\/strong> incorporados, junto al texto articulado, del DB SI<br \/>\n<em>Nota: Indicamos en cursiva la parte de aquellos comentarios cuyo contenido ya era existente en versiones anteriores.<\/em><\/p>\n<p style=\"text-align: justify;\"><strong><span style=\"text-decoration: underline;\">II \u00c1mbito de aplicaci\u00f3n (Introducci\u00f3n)<\/span><\/strong><br \/>\n<strong>Reglamentaci\u00f3n aplicable a las zonas de engrase y lavado, talleres, estaciones de servicio, etc., integradas en aparcamientos.<\/strong><br \/>\nLas zonas de un aparcamiento destinadas a <strong>engrase y lavado, talleres<\/strong>, etc. son de <strong>uso industrial<\/strong> seg\u00fan el art\u00edculo 2 del RSCIEI, aunque no sean establecimientos diferentes del aparcamiento, por lo que se les debe aplicar dicho reglamento.<br \/>\nEn cambio, las zonas destinadas exclusivamente al <strong>lavado manual de veh\u00edculos<\/strong> <strong>no cabe considerarlas como un riesgo industrial<\/strong>, por lo que se les debe aplicar las mismas condiciones del DB SI que al conjunto del aparcamiento.<br \/>\nA las zonas destinadas a estaci\u00f3n de servicio se les debe aplicar la ITC MI-IP04 del Reglamento de Instalaciones Petrol\u00edferas.<br \/>\n<em>En cambio, las zonas destinadas exclusivamente a lavado de veh\u00edculos no cabe considerarlas como un riesgo industrial, por lo que se les debe aplicar las mismas condiciones del DB SI que al conjunto del aparcamiento.<\/em><\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>II Criterios generales de aplicaci\u00f3n (Introducci\u00f3n)<\/strong><\/span><br \/>\n<strong>Establecimientos para actividades profesionales<\/strong><br \/>\nSe considera que aquellos establecimientos que sean de \u00ab<strong>peque\u00f1a entidad<\/strong>\u00bb en los\u00a0 que las personas acuden citadas de forma personalizada y en un n\u00famero limitado (se puede considerar razonable establecer dicho l\u00edmite en 100 m2 de superficie \u00fatil y en 10 personas de ocupaci\u00f3n) pueden asimilarse, en el caso de que no lo sean, al <strong>uso Administrativo<\/strong>.<\/p>\n<p style=\"text-align: justify;\"><strong>Aplicaci\u00f3n del DB-SI en obras de mantenimiento<\/strong><br \/>\nEl CTE es de aplicaci\u00f3n a las intervenciones en edificios existentes, entendiendo por tales (ver Anejo III Terminolog\u00eda de la Parte I) las<strong> ampliaciones, las reformas y los cambios de uso<\/strong>.<br \/>\nA su vez, se entiende por reforma \u201ccualquier trabajo u obra en un edificio existente distinto del que se lleve a cabo para el exclusivo <strong>mantenimiento<\/strong> del edificio.\u201d Y a su vez, se entiende por mantenimiento el \u201cconjunto de trabajos y obras a efectuar peri\u00f3dicamente para prevenir el deterioro de un edificio o reparaciones puntuales que se realicen en el mismo, con el objeto mantenerlo en buen estado para que, con una fiabilidad adecuada, cumpla con los requisitos b\u00e1sicos de la edificaci\u00f3n establecidos.\u201d<br \/>\nEn consecuencia, en una obra que conforme a lo anterior sea de mantenimiento <strong>no es exigible la aplicaci\u00f3n del CTE<\/strong>.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>VI Laboratorios de ensayo (Introducci\u00f3n)<\/strong><\/span><br \/>\n<strong>Vigencia de los informes de extensi\u00f3n de la aplicaci\u00f3n de los resultados de los ensayos (EXAP)<\/strong><br \/>\nLos informes de extensi\u00f3n de la aplicaci\u00f3n de los resultados de los ensayos (EXAP) deben basarse en la norma aplicable vigente (EN EXAP). Cuando esta no exista, deben basarse en su \u00faltimo proyecto disponible (prEN EXAP) y cuando este tampoco exista, en la experiencia del laboratorio si bien, en este caso, su validez queda al margen del \u00e1mbito de aplicaci\u00f3n del CTE.<\/p>\n<p style=\"text-align: justify;\"><em>Los informes EXAP basados en la experiencia de un laboratorio se deben anular cuando se disponga de un prEN EXAP.<\/em><br \/>\n<em>Los informes basados en un prEN EXAP se deben actualizar cuando se disponga de un proyecto posterior o bien de una norma EN EXAP.<\/em><br \/>\n<em>Cuando se modifique una norma EN EXAP, los informes realizados conforme a ella se deben anular y revisar de acuerdo a la nueva norma, aunque los informes de ensayo en los que se base el informe EXAP est\u00e9n en vigor.<\/em><br \/>\n<em>Un informe EXAP pierde su vigencia cuando la pierda alguno de los informe de ensayo en los que se basa.<\/em><br \/>\n<em>Los informes EXAP los deben elaborar laboratorios acreditados para la realizaci\u00f3n de ensayos por una entidad oficialmente reconocida.<\/em><\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Compartimentaci\u00f3n en sectores de incendio (SI 1 apartado 2)<\/strong><\/span><br \/>\n<strong>Titularidad de un establecimiento<\/strong><br \/>\nDos zonas con diferentes usos de un mismo establecimiento, es decir bajo la misma titularidad, no precisan <strong>sectorizarse<\/strong> salvo en los casos que se establecen en SI 1-1, tabla 1.1.<br \/>\nDebe distinguirse el titular de la titularidad. Si hay un mismo titular pero dos titularidades legales diferenciadas (dos licencias) no cabr\u00eda hablar de un establecimiento, sino de dos, en cuyo caso las <strong>sectorizaci\u00f3n<\/strong> entre ellos ser\u00eda <strong>obligatoria<\/strong>, como se indica en la tabla antes citada.<\/p>\n<p style=\"text-align: justify;\"><!--more--><\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Locales y zonas de riesgo especial (SI 1 apartado 2)<\/strong><\/span><br \/>\n<strong>Clasificaci\u00f3n de almacenes<\/strong><br \/>\nPara clasificar <strong>almacenes<\/strong> en el \u00e1mbito de aplicaci\u00f3n del DB SI puede ser de ayuda el trabajo realizado por Pedro \u00c1lvarez Morales: La clasificaci\u00f3n del riesgo debido a los almacenamientos situados en edificios habitados. <strong>M\u00e9todo CRAEH<\/strong>.<br \/>\nVer el siguiente enlace en la p\u00e1gina web de CEPREVEN:<br \/>\nhttp:\/\/www.cepreven.com\/CRAEH<\/p>\n<p style=\"text-align: justify;\"><strong>Cocinas integradas en diferentes usos<\/strong><br \/>\nEn usos distintos de Hospitalario o Residencial P\u00fablico el proyectista puede decidir cu\u00e1ntos aparatos y cu\u00e1les protege, teniendo en cuenta dos cuestiones:<br \/>\na) Conforme a SI 4-1, la potencia de los aparatos que no se protejan <strong>no puede exceder de 50 kW<\/strong>.<br \/>\nb) La <strong>potencia<\/strong> de los aparatos que no se protejan es la que hay que considerar para clasificar el recinto como de riesgo bajo (&gt;20 kW) o medio (&gt;30 kW) a efectos de las exigencias que se establecen en la tabla 2.2 de SI 1-2. Dado que se tiene que cumplir la condici\u00f3n a) nunca se puede dar la circunstancia de tener que considerar el recinto como riesgo alto.<br \/>\n<em>Por ejemplo, en un restaurante (zona de uso P\u00fablica Concurrencia) que constituya un sector de incendio diferenciado en <\/em><em>un hotel (uso Residencial P\u00fablico; seg\u00fan SI 1-1, tabla 1.1, debe serlo obligatoriamente si su ocupaci\u00f3n excede de 500 <\/em><em>personas) su cocina no precisa ser local de riesgo especial, pudiendo por tanto carecer de compartimentaci\u00f3n con el <\/em><em>resto del sector restaurante, al tener que disponer obligatoriamente de un sistema autom\u00e1tico de extinci\u00f3n si la potencia <\/em>instalada excede de 50 kW.<br \/>\n<em>En cambio, las cocinas de establecimientos de uso Hospitalario o Residencial P\u00fablico deben considerarse local de riesgo <\/em><em>especial en funci\u00f3n de los l\u00edmites de potencia instalada que se establecen en la tabla 2.1, con independencia de que <\/em><em>cuenten o no con sistema autom\u00e1tico de extinci\u00f3n. Seg\u00fan la tabla 1.1 del art\u00edculo SI 4-1 deben contar obligatoriamente <\/em><em>con dicha instalaci\u00f3n cuando la potencia instalada exceda de 20 kW. En esos casos, el recinto se debe tratar como riesgo <\/em><em>especial bajo, medio o alto si la potencia instalada (es decir, la de todos los aparatos, protegidos o no) excede de 20, 30 <\/em><em>o 50 kW, respectivamente.<\/em><br \/>\n<em>La regulaci\u00f3n de las caracter\u00edsticas del sistema autom\u00e1tico de extinci\u00f3n corresponde, como para el resto de las <\/em><em>instalaciones de protecci\u00f3n contra incendio, al RIPCI.<\/em><\/p>\n<p style=\"text-align: justify;\"><strong>Garajes con plazas compartimentadas<\/strong><br \/>\n<em>Un garaje compartimentado en plazas segregadas para cada usuario, cada una de las cuales no tenga m\u00e1s de 100 m2 debe cumplir en su conjunto las condiciones del uso Aparcamiento, excepto cuando la compartimentaci\u00f3n de cada garaje individual sea EI 90, incluido el port\u00f3n para veh\u00edculos, lo que permitir\u00eda considerar al garaje como un conjunto de locales de riesgo especial bajo.<\/em><br \/>\n<em>No obstante, incluso en el primer caso deben seguir cumpli\u00e9ndose las condiciones de ventilaci\u00f3n de HS 3, aplicadas a cada garaje individual (conforme a HS 3-3.1.4.1, punto 2) y a la zona com\u00fan de circulaci\u00f3n o aplicadas globalmente al conjunto del garaje.<\/em><br \/>\nEl <strong>port\u00f3n<\/strong> para veh\u00edculos de cada plaza no es v\u00e1lido a efectos de evacuaci\u00f3n, ya sea basculante, corredero o abatible. Por tanto, cada plaza, que se debe considerar origen de evacuaci\u00f3n, debe tener, o bien una puerta de paso a las zonas comunes del aparcamiento v\u00e1lida a efectos de evacuaci\u00f3n (abatible, con eje de giro vertical y al menos 80 cm de anchura libre) que no tendr\u00eda la consideraci\u00f3n de salida de planta y que puede estar contendida en el port\u00f3n para<br \/>\nveh\u00edculos siempre que este cumpla las condiciones que se establecen en SUA 2-1.2.3., o bien en una salida de planta mediante un acceso a la vivienda asociada a la plaza de aparcamiento con vest\u00edbulo de independencia, como es preceptivo en toda comunicaci\u00f3n entre un aparcamiento y otro sector de otro uso. Si la comunicaci\u00f3n entre la plaza de aparcamiento y la vivienda es mediante una escalera, el vest\u00edbulo de independencia puede estar optativamente en la planta del garaje, en la planta de la vivienda o estar constituido por la propia escalera, siempre que est\u00e9 convenientemente compartimentada, incluso en lo que se refiere a sus puertas.<br \/>\nSi los <strong>accesos<\/strong> desde las plazas de aparcamiento a las viviendas precisan ser salidas de planta deben cumplir lo que establece el punto 1 de SI 3-6, lo cual no supone necesariamente que dichas puertas carezcan de cerradura con llave, sino que en <strong>horario de actividad<\/strong> (es decir, trat\u00e1ndose de viviendas, en todo momento) dicho cierre no act\u00fae, lo cual constituye una exigencia al usuario, no al proyecto. Si esto no fuera posible, se debe resolver la evacuaci\u00f3n desde las plaza de aparcamiento mediante las salidas de las plazas citadas anteriormente y las posteriores salidas de planta del garaje respecto de las cuales se cumpla la condici\u00f3n de m\u00e1ximo <strong>recorrido admisible<\/strong>.<\/p>\n<p style=\"text-align: justify;\"><strong>Espacios ocultos (SI 1 apartado 3)<\/strong><br \/>\n<strong>Conductos pasantes con resistencia al fuego igual a la del elemento atravesado<\/strong><br \/>\nCuando se opta por la soluci\u00f3n de dotar de resistencia al fuego a un conducto que atraviesa un elemento de <strong>sectorizaci\u00f3n<\/strong>, toda su longitud de paso por al menos uno de los sectores cuya compartimentaci\u00f3n atraviesa debe tener la resistencia requerida.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Dimensionado de los medios de evacuaci\u00f3n (SI 3 apartado 4)<\/strong><\/span><br \/>\n<strong>Anchura libre de puertas seg\u00fan DB SI y DB SUA<\/strong><br \/>\nEl DB-SI establece condiciones desde el punto de vista de la <strong>evacuaci\u00f3n<\/strong> y el DB-SUA desde el punto de vista de la <strong>accesibilidad<\/strong>. Cuando se trata de un elemento de evacuaci\u00f3n que est\u00e1 situado en un itinerario accesible hay que cumplir las condiciones de ambos DB. Es decir, que prevalecen las que sean m\u00e1s exigentes.<br \/>\nNo obstante, en lo relativo a la <strong>anchura de paso m\u00ednima de las puertas<\/strong> puede aplicarse en el DB-SI el mismo criterio que en el DB-SUA, es decir, que en el \u00e1ngulo de m\u00e1xima apertura se admite que la anchura libre de paso reducida por el grosor de la hoja de la puerta sea L 0,78 m.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Puertas situadas en recorridos de evacuaci\u00f3n (SI 3 apartado 6)<\/strong><\/span><br \/>\n<strong>Apertura en sentido de la evacuaci\u00f3n<\/strong><br \/>\n<em>El n\u00famero de personas que obliga a que una puerta abra en el <strong>sentido de la evacuaci\u00f3n<\/strong> es 51 cuando provienen \u201cdel recinto o espacio en el que est\u00e9 situada\u201d la puerta, o 101 cuando provienen de ese y de otros espacios.<\/em><br \/>\n<em>Con este art\u00edculo se pretende poner el l\u00edmite en 50 personas cuando se prevea que estas puedan llegar a la puerta <strong>simult\u00e1neamente<\/strong> y de forma inmediata a la declaraci\u00f3n de la emergencia, y en 100 personas cuando sea previsible un cierto grado de <strong>secuencialidad<\/strong> en la llegada de los ocupantes a la puerta.<\/em><\/p>\n<p style=\"text-align: justify;\"><em>En determinados casos, la decisi\u00f3n acerca de qu\u00e9 limite aplicar depender\u00e1, m\u00e1s all\u00e1 de la literalidad del art\u00edculo, de c\u00f3mo se valore dicha simultaneidad o secuencialidad, a la vista de la configuraci\u00f3n concreta de cada caso.<\/em><\/p>\n<p style=\"text-align: justify;\">Por otro lado, como consecuencia de la aplicaci\u00f3n de los puntos 2 y 3 de este apartado, toda puerta que sea <strong>salida de planta o de edificio<\/strong> y que tenga sistema de cierre que act\u00fae en horario de actividad (las hay que no lo tienen o no act\u00faa; basta tirar o empujar) y dicho sistema de cierre deba ser un mecanismo conforme a UNE-EN 1125 (<strong>barra antip\u00e1nico<\/strong>) por ser la mayor\u00eda ocupantes no familiarizados, debe abrir en el sentido de la evacuaci\u00f3n, aunque sea para menos de 50 ocupantes.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Evacuaci\u00f3n de personas con discapacidad en caso de incendio (SI 3 apartado 9)<\/strong><\/span><br \/>\n<strong>Condiciones de las salidas accesibles<\/strong><br \/>\nA las <strong>salidas accesibles<\/strong> se les aplican las mismas condiciones que a las salidas de planta, en cuanto a:<br \/>\n&#8211; <strong>n\u00famero<\/strong> necesario (una o m\u00e1s de una)<br \/>\n&#8211; <strong>recorrido<\/strong> total m\u00e1ximo hasta alguna de ellas desde todo punto susceptible de ser ocupado por una persona con discapacidad (que en este caso no siempre es todo origen de evacuaci\u00f3n)<br \/>\n&#8211; el recorrido m\u00e1ximo hasta un punto con recorrido <strong>alternativo<\/strong><br \/>\n&#8211; criterio de bloqueo<br \/>\nEn zonas de <strong>refugio<\/strong> y sectores alternativos se debe aplicar este \u00faltimo gui\u00f3n a efectos de dimensionar el n\u00famero de plazas necesario en cada zona.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Origen de evacuaci\u00f3n (Anejo SI A)<\/strong><\/span><br \/>\n<strong>Altura libre para considerar origen de evacuaci\u00f3n<\/strong><br \/>\nEn un espacio con techo <strong>abuhardillado<\/strong> se puede considerar que los puntos con altura libre menor de 1,50 m no son origen de evacuaci\u00f3n.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Salida de planta (Anejo SI A)<\/strong><\/span><br \/>\n<strong>Salidas de planta entre sectores seg\u00fan evacuaci\u00f3n secuencial o simult\u00e1nea<\/strong><br \/>\nLa condici\u00f3n seg\u00fan la cual un sector (B) que es <strong>salida de planta<\/strong> de otro sector origen de incendio (A) debe tener superficie de albergue suficiente para los ocupantes del sector A que pasan al B a raz\u00f3n de 0,5 m2\/pers., aplicando para ello la hip\u00f3tesis de bloqueo, lleva impl\u00edcito que se est\u00e1 dise\u00f1ando para una evacuaci\u00f3n secuencial y no total y simult\u00e1nea del edificio, aunque esto \u00faltimo no se indica en el texto del DB SI. Lo que supone que las salidas del sector B no precisan dimensionarse para la suma de sus propios ocupantes m\u00e1s los que proceden del sector A.<br \/>\nPero si las salidas del sector B (p. ej. sus escaleras) se dimensionan con capacidad suficiente para la suma de ocupantes de ambos sectores la <strong>hip\u00f3tesis<\/strong> que se est\u00e1 aplicando es la de evacuaci\u00f3n total y simult\u00e1nea, la cual es m\u00e1s exigente que la secuencial. Dado que bajo esta hip\u00f3tesis los ocupantes del sector A no permanecen en el sector B, sino que circulan hacia las salidas del sector B junto con los ocupantes de este, la condici\u00f3n de que en el sector B haya superficie de albergue suficiente no es necesaria.<br \/>\nEn cualquiera de los dos escenarios, los <strong>recorridos<\/strong> de evacuaci\u00f3n del sector A se miden hasta las salidas de planta del sector A, no hasta las del B.<br \/>\nSe recuerda que la validez de aplicar la hip\u00f3tesis de evacuaci\u00f3n <strong>secuencial<\/strong>, que es la que hace exigible la condici\u00f3n de superficie de albergue suficiente en el sector alternativo, debe justificarse conforme a lo que se indica en el comentario \u201cEvacuaci\u00f3n total o secuencial\u201d de SI 3-4.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-decoration: underline;\"><strong>Sector de riesgo m\u00ednimo (Anejo SI A)<\/strong><\/span><br \/>\n<strong>Tapas y registros<\/strong><br \/>\n<em>En un sector de riesgo m\u00ednimo pueden existir tapas o registros de patinillos, conductos o armarios para instalaciones siempre que sean EI 60, como extensi\u00f3n a este caso de lo que se admite en escaleras protegidas o especialmente protegidas.<\/em><\/p>\n<p style=\"text-align: justify;\">Los <strong>armarios para contadores<\/strong> de electricidad (m\u00e1ximo 16), los armarios <strong>modulares<\/strong> de instalaciones de telecomunicaci\u00f3n inferior y los recintos para <strong>contadores<\/strong> de agua no precisan cumplir ninguna condici\u00f3n de compartimentaci\u00f3n respecto del sector de riesgo m\u00ednimo. Los recintos para contadores de <strong>electricidad<\/strong> o para instalaciones de telecomunicaci\u00f3n inferior (RITI) deben <strong>cumplir<\/strong> las condiciones del REBT y del Real Decreto 346\/2011, de 11 de marzo, respectivamente y, adem\u00e1s de ser <strong>locales de riesgo especial bajo<\/strong> conforme al DB-SI, deben estar comunicados con el sector de riesgo m\u00ednimo a trav\u00e9s de un vest\u00edbulo de independencia.<\/p>\n\n\n<div class=\"kk-star-ratings kksr-auto kksr-align-left kksr-valign-bottom\"\n    data-payload='{&quot;align&quot;:&quot;left&quot;,&quot;id&quot;:&quot;778&quot;,&quot;slug&quot;:&quot;default&quot;,&quot;valign&quot;:&quot;bottom&quot;,&quot;ignore&quot;:&quot;&quot;,&quot;reference&quot;:&quot;auto&quot;,&quot;class&quot;:&quot;&quot;,&quot;count&quot;:&quot;7&quot;,&quot;legendonly&quot;:&quot;&quot;,&quot;readonly&quot;:&quot;&quot;,&quot;score&quot;:&quot;5&quot;,&quot;starsonly&quot;:&quot;&quot;,&quot;best&quot;:&quot;5&quot;,&quot;gap&quot;:&quot;4&quot;,&quot;greet&quot;:&quot;&quot;,&quot;legend&quot;:&quot;5\\\/5 - (7 votos)&quot;,&quot;size&quot;:&quot;24&quot;,&quot;title&quot;:&quot;Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio)&quot;,&quot;width&quot;:&quot;138&quot;,&quot;_legend&quot;:&quot;{score}\\\/{best} - ({count} {votes})&quot;,&quot;font_factor&quot;:&quot;1.25&quot;}'>\n            \n<div class=\"kksr-stars\">\n    \n<div class=\"kksr-stars-inactive\">\n            <div class=\"kksr-star\" data-star=\"1\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"2\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"3\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"4\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"5\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n    <\/div>\n    \n<div class=\"kksr-stars-active\" style=\"width: 138px;\">\n            <div class=\"kksr-star\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 4px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 24px; height: 24px;\"><\/div>\n        <\/div>\n    <\/div>\n<\/div>\n                \n\n<div class=\"kksr-legend\" style=\"font-size: 19.2px;\">\n            5\/5 - (7 votos)    <\/div>\n    <\/div>\n<p id=\"bte_opp\"><small><\/small><\/p>","protected":false},"excerpt":{"rendered":"<p>Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio), del C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":784,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rop_custom_images_group":[],"rop_custom_messages_group":[],"rop_publish_now":"initial","rop_publish_now_accounts":{"twitter_17708481_17708481":""},"rop_publish_now_history":[],"rop_publish_now_status":"pending","footnotes":""},"categories":[34],"tags":[128,288,179,126,29],"class_list":["post-778","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-normativa","tag-codigo","tag-coentarios","tag-incendio","tag-legislacion","tag-normativa"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio) - Licencias de Apertura y Actividad<\/title>\n<meta name=\"description\" content=\"Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio) os remitimos un breve resumen para vuestra informaci\u00f3n:\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio) - Licencias de Apertura y Actividad\" \/>\n<meta property=\"og:description\" content=\"Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio) os remitimos un breve resumen para vuestra informaci\u00f3n:\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/\" \/>\n<meta property=\"og:site_name\" content=\"Licencias de Apertura y Actividad\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ArquitectosVillanueva\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ArquitectosVillanueva\" \/>\n<meta property=\"article:published_time\" content=\"2025-02-06T12:00:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"884\" \/>\n\t<meta property=\"og:image:height\" content=\"323\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Gorka Villanueva\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@gorkavillanueva\" \/>\n<meta name=\"twitter:site\" content=\"@gorkavillanueva\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gorka Villanueva\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/\"},\"author\":{\"name\":\"Gorka Villanueva\",\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/#\\\/schema\\\/person\\\/33c4a38b2dfdf1309dd9a667d142c13c\"},\"headline\":\"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio)\",\"datePublished\":\"2025-02-06T12:00:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/\"},\"wordCount\":2650,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/#\\\/schema\\\/person\\\/33c4a38b2dfdf1309dd9a667d142c13c\"},\"image\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/wp-content\\\/uploads\\\/licencia-normativa-indendios.jpg\",\"keywords\":[\"codigo\",\"coentarios\",\"incendio\",\"legislacion\",\"normativa\"],\"articleSection\":[\"Normativa\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/\",\"url\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/\",\"name\":\"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio) - Licencias de Apertura y Actividad\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/wp-content\\\/uploads\\\/licencia-normativa-indendios.jpg\",\"datePublished\":\"2025-02-06T12:00:55+00:00\",\"description\":\"Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio) os remitimos un breve resumen para vuestra informaci\u00f3n:\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/wp-content\\\/uploads\\\/licencia-normativa-indendios.jpg\",\"contentUrl\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/wp-content\\\/uploads\\\/licencia-normativa-indendios.jpg\",\"width\":884,\"height\":323},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/actualizacion-comentarios-normativa-incendio\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/\",\"name\":\"Licencias de Apertura y Actividad\",\"description\":\"Especializados en la tramitaci\u00f3n de licencias de actividad, licencias de apertura y declaraciones responsables. Resolvemos todas tus dudas sobre c\u00f3mo obtener tu licencia de funcionamiento y gestionar los tr\u00e1mites con el Ayuntamiento. Somos expertos en la gesti\u00f3n de aperturas de negocios. Este espacio est\u00e1 dise\u00f1ado para guiarte en el complejo mundo de las licencias de actividad y la burocracia urban\u00edstica. Aqu\u00ed encontrar\u00e1s an\u00e1lisis de normativa, gu\u00edas de procedimiento y ejemplos pr\u00e1cticos para tu negocio o local. Convierte tu proyecto en realidad con informaci\u00f3n t\u00e9cnica actualizada y fiable.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/#\\\/schema\\\/person\\\/33c4a38b2dfdf1309dd9a667d142c13c\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/#\\\/schema\\\/person\\\/33c4a38b2dfdf1309dd9a667d142c13c\",\"name\":\"Gorka Villanueva\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g\",\"caption\":\"Gorka Villanueva\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g\"},\"sameAs\":[\"http:\\\/\\\/www.madridlicencias.com\",\"https:\\\/\\\/www.facebook.com\\\/ArquitectosVillanueva\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/gorkavilla\\\/\"],\"url\":\"https:\\\/\\\/www.madridlicencias.com\\\/blog\\\/author\\\/madridli\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio) - Licencias de Apertura y Actividad","description":"Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio) os remitimos un breve resumen para vuestra informaci\u00f3n:","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/","og_locale":"es_ES","og_type":"article","og_title":"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio) - Licencias de Apertura y Actividad","og_description":"Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio) os remitimos un breve resumen para vuestra informaci\u00f3n:","og_url":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/","og_site_name":"Licencias de Apertura y Actividad","article_publisher":"https:\/\/www.facebook.com\/ArquitectosVillanueva","article_author":"https:\/\/www.facebook.com\/ArquitectosVillanueva","article_published_time":"2025-02-06T12:00:55+00:00","og_image":[{"width":884,"height":323,"url":"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg","type":"image\/jpeg"}],"author":"Gorka Villanueva","twitter_card":"summary_large_image","twitter_creator":"@gorkavillanueva","twitter_site":"@gorkavillanueva","twitter_misc":{"Escrito por":"Gorka Villanueva","Tiempo de lectura":"13 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#article","isPartOf":{"@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/"},"author":{"name":"Gorka Villanueva","@id":"https:\/\/www.madridlicencias.com\/blog\/#\/schema\/person\/33c4a38b2dfdf1309dd9a667d142c13c"},"headline":"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio)","datePublished":"2025-02-06T12:00:55+00:00","mainEntityOfPage":{"@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/"},"wordCount":2650,"commentCount":1,"publisher":{"@id":"https:\/\/www.madridlicencias.com\/blog\/#\/schema\/person\/33c4a38b2dfdf1309dd9a667d142c13c"},"image":{"@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#primaryimage"},"thumbnailUrl":"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg","keywords":["codigo","coentarios","incendio","legislacion","normativa"],"articleSection":["Normativa"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/","url":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/","name":"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio) - Licencias de Apertura y Actividad","isPartOf":{"@id":"https:\/\/www.madridlicencias.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#primaryimage"},"image":{"@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#primaryimage"},"thumbnailUrl":"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg","datePublished":"2025-02-06T12:00:55+00:00","description":"Se han actualizado los comentarios incorporados a los documentos DB-SI (Seguridad frente a incendio) os remitimos un breve resumen para vuestra informaci\u00f3n:","breadcrumb":{"@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#primaryimage","url":"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg","contentUrl":"https:\/\/www.madridlicencias.com\/blog\/wp-content\/uploads\/licencia-normativa-indendios.jpg","width":884,"height":323},{"@type":"BreadcrumbList","@id":"https:\/\/www.madridlicencias.com\/blog\/actualizacion-comentarios-normativa-incendio\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.madridlicencias.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Actualizaci\u00f3n de comentarios normativa DB-SI (Seguridad frente a Incendio)"}]},{"@type":"WebSite","@id":"https:\/\/www.madridlicencias.com\/blog\/#website","url":"https:\/\/www.madridlicencias.com\/blog\/","name":"Licencias de Apertura y Actividad","description":"Especializados en la tramitaci\u00f3n de licencias de actividad, licencias de apertura y declaraciones responsables. Resolvemos todas tus dudas sobre c\u00f3mo obtener tu licencia de funcionamiento y gestionar los tr\u00e1mites con el Ayuntamiento. Somos expertos en la gesti\u00f3n de aperturas de negocios. Este espacio est\u00e1 dise\u00f1ado para guiarte en el complejo mundo de las licencias de actividad y la burocracia urban\u00edstica. Aqu\u00ed encontrar\u00e1s an\u00e1lisis de normativa, gu\u00edas de procedimiento y ejemplos pr\u00e1cticos para tu negocio o local. Convierte tu proyecto en realidad con informaci\u00f3n t\u00e9cnica actualizada y fiable.","publisher":{"@id":"https:\/\/www.madridlicencias.com\/blog\/#\/schema\/person\/33c4a38b2dfdf1309dd9a667d142c13c"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.madridlicencias.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":["Person","Organization"],"@id":"https:\/\/www.madridlicencias.com\/blog\/#\/schema\/person\/33c4a38b2dfdf1309dd9a667d142c13c","name":"Gorka Villanueva","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g","caption":"Gorka Villanueva"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/2b22df0b555528a455bd6d7a4d62706746a36d31559440cca3a43072b34ff7ad?s=96&d=mm&r=g"},"sameAs":["http:\/\/www.madridlicencias.com","https:\/\/www.facebook.com\/ArquitectosVillanueva","https:\/\/www.linkedin.com\/in\/gorkavilla\/"],"url":"https:\/\/www.madridlicencias.com\/blog\/author\/madridli\/"}]}},"_links":{"self":[{"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/posts\/778","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/comments?post=778"}],"version-history":[{"count":7,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/posts\/778\/revisions"}],"predecessor-version":[{"id":1420,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/posts\/778\/revisions\/1420"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/media\/784"}],"wp:attachment":[{"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/media?parent=778"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/categories?post=778"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.madridlicencias.com\/blog\/wp-json\/wp\/v2\/tags?post=778"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}